26G IV Cannula: The Smallest Size in the Standard Colour Code

EMIS+ Clinical Team

Quick answer: A 26G IV cannula is the thinnest size in the international colour code for peripheral IV cannulas. Its plastic tube has a nominal outside diameter of 0.6 mm and its hub is violet. The UK medicines and devices regulator, the MHRA, described BD Neoflon in a 2013 Medical Device Alert as a cannula for neonatal, paediatric and geriatric patients, and the clinician picks the size to suit the vein and the treatment. It is not the thinnest needle of every kind, because insulin pen needles are thinner, but among standard IV cannulas nothing in the code is smaller. The price of that small size is flow: fluid runs through a 26G more slowly than through a 24G.

By the EMIS+ Clinical Team. Published 23 November 2026.

We get asked about 26G by clinic buyers who have only ever ordered yellow and blue cannulas, and by parents who have seen a tiny violet one in a baby's hand in the neonatal unit. This page explains what the number means, who the size is for, what you give up by going that small, and what to check on the box before you order.

What does 26G mean on an IV cannula?

The G stands for gauge, and the scale runs backwards: the higher the number, the thinner the cannula. A 26G is thinner than a 24G, which is thinner than a 22G.

The sizes are set out in ISO 10555-5, the international standard for over-needle peripheral catheters. The standard actually sizes a cannula by the outside diameter of its plastic tube in millimetres and gives each size a hub colour. The gauge number is listed beside it as an optional label, which is why a box may show both "26G" and "0.6 mm".

Gauge Hub colour Nominal outside diameter Allowed range
26G Violet 0.6 mm 0.550 to 0.649 mm
24G Yellow 0.7 mm 0.650 to 0.749 mm
22G Deep blue 0.8 or 0.9 mm 0.750 to 0.949 mm

The code ties the colour to the diameter, so violet stands for a nominal 0.6 mm cannula. The size is also printed on the label, and that is the thing to check. Some makers print "purple" on the box. It is the same colour code.

Is 26G really the smallest IV cannula?

Within the standard colour code, yes. The table in ISO 10555-5 begins at 0.6 mm, violet, 26 gauge. There is no smaller row.

That is a narrower claim than "the smallest needle on the market", and the difference matters. Needles for other jobs go thinner. Insulin pen needles are one example. They are short needles for injecting under the skin and they cannot stay in a vein. An IV cannula is a different device: a needle carries a soft plastic tube into the vein, the needle comes out, and the tube stays in place to carry fluid or medicine. For that kind of device, 26G is the bottom of the standard range.

Who is a 26G cannula used for?

That MHRA alert names neonatal, paediatric and geriatric patients, and most of the published work on this size is in babies. A UK neonatal study registered with the NHS Health Research Authority compared 24G and 26G cannulas in babies born before 32 weeks and weighing under 1.5 kg at birth. NYSORA's teaching material on IV access in children says a short 24G or 26G catheter usually suits paediatric patients.

The peripheral IV procedure for the Newborn Care Centre at the Royal Hospital for Women in Sydney lists a 24G cannula 14 mm long in its standard equipment. The 26G is the next size down, and the clinician decides whether the vein and the treatment call for it.

The gauge is always the decision of the doctor or nurse placing the line. They weigh the size of the vein against what has to go through it.

How much slower is the flow through a 26G?

A thinner tube carries less fluid per minute. The summary of the UK study above gives 22 mL a minute for its 24G cannula and 15 mL a minute for its 26G. That is roughly a third less.

Whether that flow is enough depends on the patient and on what has been prescribed, and the care team makes that call. When fluid has to go in quickly, the care team chooses the access that suits the patient and the treatment.

Flow figures vary with the brand and the length of the cannula. Go by the manufacturer's instructions and stated flow rate for the exact cannula you have.

Why does cannula size matter so much in babies?

Because complications with IV lines in babies are common. A study of 23,858 venous access devices placed in one neonatal intensive care unit in Qatar between 2016 and 2018 found that 21,313 of them, or 89%, were peripheral IV cannulas. A complication was recorded in 51% of the peripheral devices. The study did not test whether a smaller cannula lowers that figure. The authors concluded that peripheral cannulas should be used carefully and watched closely.

A line that fails may have to be replaced if the baby still needs IV treatment. The Sydney procedure limits each clinician to 2 attempts before someone else takes over, and it lists oral sucrose for comfort during the procedure.

The UK study was set up on the reasoning that a smaller cannula may be easier to insert and may cause less vein irritation. That is the question the study was designed to test. It is not a proven result, and we would not buy 26G on that promise alone.

What should you check before ordering 26G cannulas?

Match the box to what your team already uses. A cannula that looks similar can still handle differently.

  • Gauge and colour: 26G, violet hub, 0.6 mm
  • Length of the cannula in millimetres
  • With or without wings, and with or without an injection port
  • Standard or safety design, where the needle tip is shielded after use
  • Number of cannulas in the box, and the expiry date
  • Sterile packs that are sealed and undamaged

EMIS+ supplies the BD Neoflon 26G IV cannula at S$165 for a box of 50. You will find it with our other IV, infusion and vascular access supplies. If your patient goes home with a longer-term line instead, our guide to PICC line care at home covers flushing and dressing changes. For stock, other gauges or bulk orders, contact the EMIS+ team.

This content is for education only and does not replace medical advice or your facility's cannulation policy. IV cannulas should be inserted only by trained healthcare professionals, following the manufacturer's instructions for use.

Frequently asked questions

Is 26G the smallest IV cannula?

In the colour code that the international standard ISO 10555-5 sets for peripheral IV cannulas, yes. The table starts at a nominal outside diameter of 0.6 mm, which is violet and matches 26 gauge. The next size up is 0.7 mm, yellow, 24 gauge. Other kinds of needle, such as insulin pen needles, are thinner, but they are different devices.

What colour is a 26G cannula?

Violet. The standard ties the colour to the outside diameter of the plastic tube, so a violet hub means a nominal 0.6 mm cannula under that code. Check the size printed on the label as well. Some manufacturers call the same colour purple on their packaging. Yellow is 24G and deep blue is 22G, so the colours can be told apart at a glance on a busy ward.

How fast does fluid run through a 26G cannula?

Slower than through a 24G. The summary of a UK neonatal study gives 15 mL a minute for its 26G cannula and 22 mL a minute for its 24G, roughly a third less. Figures differ by brand and length, so go by the manufacturer's stated flow rate for the cannula you are using.

Can a parent or carer insert an IV cannula at home?

No. Putting in an IV cannula is a clinical procedure done by trained doctors and nurses using sterile technique. If a home care nurse has asked you to buy cannulas for a planned visit, ask them for the exact brand, gauge and length, and keep the box sealed and dry until they arrive.

Where can I buy 26G IV cannulas in Singapore?

EMIS+ supplies BD Neoflon 26G IV cannulas in boxes of 50 to clinics, nursing homes and home care nursing teams, with delivery across Singapore. You can order at emis.asia or message the team on WhatsApp at +65 8139 8668 to check stock, ask about other gauges or arrange a bulk order.

Sources

Clinical review: EMIS+ Clinical Team. This article is for general information and does not replace professional medical advice.

Back to blog