Bbraun
Infusomat Space Line IV Administration Set 250cm Luer Lock
Infusomat Space Line IV Administration Set 250cm Luer Lock
Couldn't load pickup availability
A 250 cm dedicated IV administration set designed for use with the B Braun Infusomat Space and Spaceplus large volume infusion pumps. Features Luer Lock connector, integrated anti-free-flow (AFF) clamp, 15 µm inline particulate filter, and pump-specific cassette segment compatible with Infusomat Space pump detection chambers. Indicated for controlled delivery of large-volume parenterals, TPN, IV antibiotics, and chemotherapy admixtures in hospital and home care settings.
Product Specifications
| Parameter | Value |
|---|---|
| Compatible Pump | B Braun Infusomat Space / Spaceplus large volume pump |
| Tubing Length | 250 cm |
| Patient Connector | Luer Lock (ISO 594-1 / ISO 80369-7 compatible) |
| Spike / Container Connector | Vented spike for IV bags and bottles |
| Inline Filter | 15 µm particulate filter in drip chamber |
| Anti-Free-Flow (AFF) | Integrated AFF clamp — automatically closes when set is removed from pump cassette |
| Flow Rate Range | 0.1 – 999 mL/h (pump-controlled via Infusomat Space) |
| Pump Cassette Segment | Pump-specific peristaltic segment for Infusomat Space mechanism |
| Drip Chamber Volume | Macro drip (20 drops/mL) |
| Tubing Material | DEHP-free PVC / polyolefin composite |
| Sterile / Single-Use | Yes — EO sterilised; single-use, discard after 24–72 h per institutional protocol |
| Regulatory | CE marked; HSA-registered (Singapore); FDA 510(k) cleared equivalent class |
| Standard Compliance | ISO 8536-4 (infusion sets); IEC 60601-2-24 (pump compatibility) |
| Latex-Free / DEHP-Free | Yes / Yes |
Clinical Indications
- Total Parenteral Nutrition (TPN) and home parenteral nutrition (HPN) via Infusomat Space pump
- IV antibiotic therapy (IVAB) in hospital and outpatient parenteral antibiotic therapy (OPAT) programmes
- Chemotherapy admixture infusion requiring precise volumetric delivery
- High-risk infusions requiring anti-free-flow protection — concentrated electrolytes, opioids, vasoactives
- Palliative and home care continuous subcutaneous or IV infusion
- Prolonged infusions (>4 hours) where long tubing length (250 cm) allows patient mobility
Community Consensus: Clinical Q&A
Q: Why use the 250 cm set versus the standard 150 cm set?
The 250 cm tubing provides approximately 1 metre of additional reach, enabling patient mobility during ambulatory or home infusion therapy — the patient can ambulate or reposition without disconnecting the pump. This is particularly important in home TPN, OPAT, and palliative care settings where patients are encouraged to maintain activity during infusion. The 150 cm set is preferred in ICU or ward settings where pump proximity is fixed.
Q: Does the anti-free-flow clamp activate automatically?
Yes. The integrated AFF clamp on the Infusomat Space Line set automatically closes the tubing when the cassette segment is disengaged from the pump mechanism — for example, when opening the pump door during a set change or alarm response. This prevents uncontrolled gravity-driven free flow of infusate, which is a patient safety requirement for high-risk medications including opioids, electrolyte concentrates, and chemotherapy agents. The AFF mechanism complies with IEC 60601-2-24 safety standards for infusion equipment.
Q: How often should the Infusomat Space Line set be changed?
CDC and INS guidelines recommend IV administration set changes every 96 hours for standard crystalloid infusions, every 24 hours for lipid-containing TPN (including 3-in-1 admixtures), and every 12–24 hours for blood products. Institutional infection control protocols may be more conservative. The set must be changed immediately on any sign of contamination, disconnection, or pump error. All used sets should be disposed of as clinical waste per Singapore NEA guidelines.
Q: Is the Infusomat Space Line set compatible with the Spaceplus pump variant?
Yes. The Infusomat Space Line set (including the 250 cm Luer Lock variant) is compatible with both the Infusomat Space and Infusomat Spaceplus pump models. The peristaltic cassette segment is identical between models, as is the AFF mechanism engagement. Always confirm compatibility using the pump's set recognition function before initiating infusion — the Spaceplus display will confirm set loading when correctly seated.
Q: Is this administration set available for B2B purchase in Singapore?
Yes. EMIS (Essential Medical International Supplies Pte Ltd) distributes B Braun Infusomat Space Line sets in Singapore, including the 250 cm Luer Lock variant. Available for licensed hospitals, day surgery centres, polyclinics, and registered home care providers. Contact EMIS for B2B pricing, bulk order terms, and compatibility confirmation with your specific pump firmware version.